AIR CONDITIONING INSTALLATION
Service Description
Charge from installer to customer
Cleaning of refrigerant pipes with nitrogen, per installation, in cases of:
- Where there are open pipes.
- Moisture in the circuit: €10.00
Removal of air conditioner (9000-24000 BTU): €20.00
Use of additional copper pipes (per meter): - For air conditioners 9K to 14K BTU: €18.00
- For air conditioners 16K to 24K BTU: €20.00
Adding refrigerant gas in cases where the distance from the outdoor unit to the indoor unit exceeds the manufacturer’s recommended distance (per kilogram): Base charge: €15.00
- €50.00/kg
Use of additional water drainage pipe (per meter): €3.00
Use of additional power supply cable cover duct (per meter): €6.50
Use of copper pipe cover duct (per meter): €12.00
Installation of heater switch:
- In existing box: €20.00
- In another location with external box: €35.00
Installation of external isolator according to the regulations of the Electricity Authority:
- If armored cable is needed (per meter): €3.00
- If a technician is needed for inspection by the Electricity Authority: €50.00
- On-site technician presence: €50.00
Installation of plastic floor base for outdoor unit: €30.00
Installation of metal wall base for outdoor unit:
- For air conditioners 9K to 14K BTU: €35.00
- For air conditioners 16K to 24K BTU: €40.00
Use of lifting machine (per hour): €59.50
- There may be additional charges for more difficult installations that cannot be calculated in advance.
- Our company does not undertake drilling in concrete or stone walls, columns, or beams.
- All prices above include VAT.
The term “installation” includes the following services:
- Unpacking the unit.
- Installing and connecting the air conditioner at a location specified by the customer or indicated based on the conditions of the space (according to necessary requirements).
- Demonstration of use and explanation of basic functions and components.
Installation Requirements:
- The maximum distance between the indoor and outdoor units is 3 meters, which includes the connecting cable of the air conditioner to the power supply and the water drainage pipes from the indoor unit.
- All cables are covered with trunking; copper pipes are separately insulated with Armaflex and bundled together with white adhesive tape.
- In all air conditioners, the power supply must be connected to a Heater Switch, unless the customer prefers a 13Amp plug only for air conditioners from 9K – 12K BTU.
- The water drainage pipe from the indoor unit extends to the ground with drainage in Heating Mode, except for high-rise buildings, where the endpoint will be discussed and agreed with the customer on-site.
- When holes are made in the wall for passing pipes, they are filled with suitable material.
- “Vacuum” is absolutely necessary on the pipes after connecting the air conditioners.